DP-297 Digital CO2 Carbon Dioxide IAQ Monitor Controller with Relay Function 4.5M Cable NDIR Sensing Probe for Green House Home, Office, Factory
There are no user manuals available for this item.
There is no software available for this item.
FEATURES
- Accurate 2-Channel low drift NDIR CO2 measurement
- With a 4.5M External CO2 sensor to be used in closed space
- Display real-time CO2 value
- Display CO2 chart with adjustable time scale (week/day/hour/min/auto)
- Auto Max. /Min. Recall on the CO2 chart
- Programmable CO2 zone value & CO2 center value to control output power on/off
- An audible alarm that warns CO2 concentration
- Target zone indicator on CO2 chart
- Built-in Day/Night auto-detection on CO2 probe to override CO2 control
- Backlight to assist the operation in a dark place
- Powered by AC100~240 VAC directly
- The sensing probe cable is 4.5 meters long to extend your measure spot 4.5 meters away from the display
- Installed with 3kA@300VAC fuse in meter to avoid damage by a power overload
SET INCLUSIONS
- 1x CO2 Meter (Controller + Sensor)
- Screws and tapes
- English Instruction Manual
- Standard factory packaging
| Measuring Range | 0~5000 ppm |
|---|---|
| Resolution | 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000) |
| Accuracy | CO2 below 3000ppm ±50ppm or ±5% of reading, whichever is greater; CO2 above 3000ppm ±7% of reading |
| Warm-Up Time | 30 seconds |
| Response Time CO2 | <2min for 63% of step changes or |
| LCD Size | 47 x 104 mm |
| Meter Size | 158 x 106 x 50 mm |
| Operating Condition | 0~50°C , 5~95% RH (avoid condensation) |
| Storage Condition | -20~ 60°C, 5~95%RH (avoid condensation) |
| Power Supply | AC100~240VAC |
| Piggyback Socket Load | 5A@250VAC; 10A@120VAC |